GC6100 Gas Chromatography with FID Detector

उत्पत्ति के प्लेस:

अनहुई, चीन

ब्रांड नाम:

Wayeal

प्रमाणन:

ISO, CE

मॉडल संख्या:

GC6100

हमसे संपर्क करें
उद्धरण मांगें
उत्पाद का विवरण
नाम:
जीसी प्रणाली
पता करने की सीमा:
2 × 10 -12g/s
डिटेक्टर:
फिड डिटेक्टर
स्तंभ मात्रा:
2 कॉलम
गुणात्मक दोहराव:
≤0.05%
पद:
16
भुगतान और शिपिंग की शर्तें
न्यूनतम आदेश मात्रा
1
मूल्य
बातचीत योग्य
पैकेजिंग विवरण
प्रति लकड़ी के मामले में एक टुकड़ा
प्रसव के समय
30 दिन
भुगतान शर्तें
एल/सी, टी/टी
आपूर्ति की क्षमता
प्रति माह 15 टुकड़े
उत्पाद का वर्णन

GC6100 Gas Chromatography with FID Detector
Technical Parameters of GC6100 Gas Chromatography

Power Supply220V ±10%, 50Hz ±2%
Ambient Temperature5°C to 40°C
Relative Humidity20% to 85%
Technical Specifications 
Retention Time repeatability<0.008% or <0.0008min
Peak Area Repeatability≤0.5% RSD
Injection Port 
Injection PortSplit/Splitless
Maximum Operating Temperature450°C
Control Precision0.001 psi
Control Range0–100 psi
Gas Control ModesConstant pressure, constant flow, programmed pressure/flow ramps
Maximum Split Ratio12,500:1
Optional Carrier GasesN₂, H₂, He, Ar
Flow Rate Range (N₂ as carrier gas)0–500mL/min
Column Oven 
Temperature Range Ambient +4°C to 450°C
Programmable Temperature Ramps32 steps/33 platforms
Maximum Heating Rate≥75°C/min
Cooling Time (22°C ambient)From 450°C to 50°C in <5 minutes
Maximum Program Run Time9999.99 minutes
FID Detector 
Maximum Operating Temperature450°C
Minimum Detectability≤1.5pg/s
Linear Range≥10⁷
DataAcquisition RateUp to 1000 Hz (provide proof of software interface)
ECD Detector 
Minimum Detectability≤4×10⁻¹⁵ g/mL
Linear Rang≥10⁴
TCD Detector 
Sensitivity≥60,000 mV·mL/mg
Linear Range≥10⁴
Instant Noise≤0.1 mV
Baseline Drift≤0.2 mV
Autosampler 
Sample Capacity16 positions
Solvent Bottle Positions2
Waste Bottle Position1
Syringe Cleaning ModesStandalone, pre-injection, post-injection
Injection Volume0.1–5μL

Product Performance

1. High precision

1.1 Very low noise, FID noise is better than the international leading level;
1.2 High sensitivity detector, low baseline drift;
1.3 Good reproducibility of peak area and retention time;

1.4 High temperature control accuracy and good stability, the column thermostat provides a constant temperature environment for the effective separation and detection of various components.

2. Flexibility and scalability

2.1 Optional multiple detectors (FID, FPD, ECD);
2.2 Any two detectors and two chromatographic columns can be installed at the same time; It can have three independent circuits, gas system and three signal output terminals at the same time;

2.3 Flexible syringe injection system, optional autosampler or six-port valve injection.

 
Product Application

Environmental Protection: Trace Toxicants in Air and Water Contaminated Areas Analysis, monitoring and research

Biochemistry: clinical applications, pathology and toxicology studies.